Installation
P_SI_0012_SW
Fig. 14: Direction of rotation of motor
Stroke sensor (Option)
Other units
28
CAUTION!
The motor may be damaged
The motor is not equipped with a fuse.
Install a suitable motor protection switch.
1.
Use a suitable cable between the motor terminal box and
power supply.
2.
Install an emergency cut-off switch or include the motor in the
emergency cut-off management of the system.
Key motor data can be found on the unit name‐
plate.
Motor data sheets can be requested for more infor‐
mation.
The terminal wiring diagram is located in the ter‐
minal box.
Notes on the speed controlled motor with external
fan and temperature monitoring can be found in
the "General operating instructions for ProMinent
motor-driven metering pumps and hydraulic acces‐
sories"!
The external fan requires an independent mains con‐
nection.
Connect the stroke sensor to a suitable monitoring device
according to the details in the chapter "Technical Data". Also
observe its technical data.
Install the other units according to their documentation.
®