Functions
4.7
Error Behavior
If the ME3CAN1-L detects a failure during NMT state Operational it will automatically change to NMT
state Pre-operational by default. Alternatively the ME3CAN1-L can be configured to change to the
NMT state Stopped or remain in the current NMT state.
The following failures can be detected:
● Bus-OFF conditions of the CAN interface
● Only as NMT Slave:
– Life guarding event with the state 'occurred' and the reason 'time out'
– Heartbeat event with state 'occurred' and the reason 'time out'
● PLC RUN
can be set again to Operational when the PLC is in STOP.
With the setting value 00
is in STOP.
Severe CANopen device errors also may be caused by CANopen device internal failures.
Object 1029
Value (hex)
03–FE
Tab. 4-26: Error class values
PLC RUN
tional also when the PLC is in STOP.
4 – 34
STOP: If the setting value is 01
or 02
H
, Sub-index 01
: Error behavior object
H
H
Description
00
Change to NMT state Pre-operational (only if currently in NMT state Operational)
01
No change of the NMT state
02
Change to NMT state Stopped
Not used
STOP: In case setting value 01
, the ME3CAN1-L will change into Pre-operational but
H
, the ME3CAN1-L cannot set into Operational as long as the PLC
H
the ME3CAN1-L will change into Pre-operational but can be set again to Opera-
H
Error Behavior