Module 72 - Switching Input/Output Swio3 - Leuze electronic BCL548i Manual

Table of Contents

Advertisement

10.13.7 Module 72 – Switching input/output SWIO3
PROFINET-IO module identifier
Module-ID
Submodule-ID
Parameter
Parameter
Function
DC bias level
Reserved
Start-up delay
Switch-on time
Switch-on
function 1
Switch-on
function 2
Switch-off
function 1
Switch-off
function 2
Comparative
value
(Event Counter)
Compare mode
(Event Counter)
Table 10.47:
Leuze electronic
1072
1
Description
This parameter defines whether
I/O 3 functions as an input or as an
output.
Mode of operation for configuration as an output
The parameter defines the DC bias
level of the switching output and,
thus, simultaneously whether the
output is low-active (0) or high-
active (1).
Free
With this parameter, the output
pulse may be delayed by a set time
period.
The parameter defines the switch-
on time period for the switching
output. If the value is 0, the signal
is static.
This parameter specifies an event
which can set the switching out-
put.
This parameter specifies an event
which can set the switching out-
put.
Switch-on function 1 and switch-
on function 2 are OR linked.
This parameter specifies an event
which can reset the switching out-
put.
This parameter specifies an event
which can reset the switching out-
put.
Switch-off function 1 and switch-
off function 2 are OR linked.
If the number of activation events
of the selected switch-on function
reaches this comparative value,
the switching output is activated. A
deactivation event of the selected
switch-off function resets the
counter.
Specifies whether the switching
output switches only on parity
(once) or also in the event of
greater or equal to (multiple times)
after the comparative value is
reached.
Parameters for module 72 – Input/Output 3
Commissioning and configuration
Addr.
Data type
0.0
Bit
0.1
Bit
0.2 ... 0.7
1
UNSIGNED16
3
UNSIGNED16
5
UNSIGNED8
6
UNSIGNED8
7
UNSIGNED8
8
UNSIGNED8
9
UNSIGNED16
11
UNSIGNED8
BCL
548i
Value range
Default
0: Input
0
1: Output
0: LOW (0V)
0
1: HIGH (+Ub)
0 ... 65535
0
0 ... 1300
400
cf. "Switch-on/
switch-off
0
functions" on
page 180
cf. "Switch-on/
switch-off
0
functions" on
page 180
cf. "Switch-on/
switch-off
0
functions" on
page 180
cf. "Switch-on/
switch-off
0
functions" on
page 180
0..65535
0
0: SWOUT
switches
once
0
1: SWOUT
switches sev-
eral times
Unit
-
-
ms
ms
-
-
-
-
-
-
185