10.12.4 Input functions for operation as an input
Name
No function
Activation of the reading gate
Reading gate deactivation only
Reading gate activation only
Reference bar code teach-in
Start/stop autoconfiguration mode
Table 10.45:
10.12.5 Module 70 – Switching input/output SWIO1
Parameter
Parameter
Function
DC bias level
Reserved
Start-up delay
Switch-on
time
Switch-on
function 1
Switch-on
function 2
Switch-off
function 1
Switch-off
function 2
Table 10.46:
Leuze electronic
Value
0
1
2
3
4
5
Input functions
Description
This parameter defines
whether I/O 1 functions as an
input or as an output.
Mode of operation for configuration as an output
The parameter defines the DC
bias level of the switching out-
put and, thus, simultaneously
whether the output is low-
active (0) or high-active (1).
Free
With this parameter, the output
pulse may be delayed by a set
time period.
The parameter defines the
switch-on time period for the
switching output. If the value is
0, the signal is static.
This parameter specifies an
event which can set the switch-
ing output.
This parameter specifies an
event which can set the switch-
ing output.
Switch-on function 1 and
switch-on function 2 are OR
linked.
This parameter specifies an
event which can reset the
switching output.
This parameter specifies an
event which can reset the
switching output.
Switch-off function 1 and
switch-off function 2 are OR
linked.
Parameters for module 70 – Input/Output 1
Commissioning and configuration
Comments
No functionality
Addr.
Data type
0.0
Bit
0.1
Bit
0.2 ... 0.7
1
UNSIGNED16
3
UNSIGNED16
5
UNSIGNED8
6
UNSIGNED8
7
UNSIGNED8
8
UNSIGNED8
BCL
304i
Value range
Default
0: Input
0
1: Output
0: LOW (0V)
0
1: HIGH (+Ub)
0 ... 65535
0
0 ... 1300
400
cf. "Switch-on/
switch-off
0
functions"
on page 140
cf. "Switch-on/
switch-off
0
functions"
on page 140
cf. "Switch-on/
switch-off
0
functions"
on page 140
cf. "Switch-on/
switch-off
0
functions"
on page 140
Unit
-
-
ms
ms
-
-
-
-
141