Switching Input: Module 13 - Leuze electronic BCL 34 Series Technical Description

Barcode reader with integrated decoder
Table of Contents

Advertisement

Leuze
electronic
7.3.10 Switching input
Module 13
The module defines the mode of operation of the digital switching input.
Parameter
Parameter
Inversion
Mode
De-bouncing
time
Start-up delay
Minimum
switch-on time
Switch-off
delay
Function
Table 7.15:
Parameter length: 10 bytes
Input Data
Input Data
State
Table 7.16:
Input data length: 1 byte
Output Data
none
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Description
The parameter defines the logic of the inci-
dent signal. In case of an inversion, an
external HIGH level is interpreted internally
as a LOW level.
The parameter can be used to control the
processing of the switching input
The parameter defines a de-bouncing time
which is implemented in software.
The parameter influences the timing during
switch-on
The parameter defines a minimum time
period before the signal is reset.
The parameter defines a time delay for the
signal during switch-off.
The parameter specifies the function which
is to be activated or deactivated by a
change of state in the signal.
Parameters for Module 13
Description
State of the signal of the switching input 0.0
Input data for Module 13
Value Range
0: No
1: Yes
0: Off
1 : On
0 ... 255
0 ... 65.535
0 ... 65.535
0 ... 65.535
0: No function
1: Activation of the
reading gate
Addr.
BCL 34
Profibus
Standard Unit
0
1
5
0
0
0
1
Data
Value
Init
Type
Range
Value Unit
Bit
0,1
0
-
-
ms
ms
ms
ms
-
-
51