Input Functions For Operation As An Input; Module 70 - Switching Input/Output Swio1; Table 10.41; Input Functions - Leuze electronic BCL348i Technical Description

Hide thumbs Also See for BCL348i:
Table of Contents

Advertisement

10.13.4 Input functions for operation as an input

Name
No function
Activation of the reading gate
Reading gate deactivation only
Reading gate activation only
Reference bar code teach-in
Start/stop autoconfiguration mode

Table 10.41:

10.13.5 Module 70 – Switching input/output SWIO1
PROFINET-IO module identifier
Module-ID
Submodule-ID
Parameter
Parameter
Function
DC bias level
Reserved
Start-up delay
Switch-on
time
Switch-on
function 1
Switch-on
function 2
Switch-off
function 1
Switch-off
function 2
Table 10.42:
Leuze electronic
Value
0
1
2
3
4
5

Input functions

1070
1
Description
This parameter defines whether I/O 1
functions as an input or as an output.
Mode of operation for configuration as an output
The parameter defines the DC bias
level of the switching output and,
thus, simultaneously whether the
output is low-active (0) or
high-active (1).
Free
With this parameter, the output pulse
may be delayed by a set time period.
The parameter defines the switch-on
time period for the switching output.
If the value is 0, the signal is static.
This parameter specifies an event
which can set the switching output.
This parameter specifies an event
which can set the switching output.
Switch-on function 1 and switch-on
function 2 are OR linked.
This parameter specifies an event
which can reset the switching output.
This parameter specifies an event
which can reset the switching output.
Switch-off function 1 and switch-off
function 2 are OR linked.
Parameters for module 70 – Input/Output 1
Commissioning and configuration
Comments
No functionality.
Addr.
Data type
0.0
Bit
0.1
Bit
0.2 ... 0.7
1
UNSIGNED16 0 ... 65535
3
UNSIGNED16 0 ... 1300
5
UNSIGNED8
6
UNSIGNED8
7
UNSIGNED8
8
UNSIGNED8
BCL
348i
Value range
Default
0: Input
1: Output
0
0: LOW (0V)
0
1: HIGH (+Ub)
0
400
cf. "Switch-on/
switch-off
0
functions" on
page 156
cf. "Switch-on/
switch-off
0
functions" on
page 156
cf. "Switch-on/
switch-off
0
functions" on
page 156
cf. "Switch-on/
switch-off
0
functions" on
page 156
Unit
-
-
ms
ms
-
-
-
-
157