Module 72 - Switching Input/Output Swio3 - Leuze electronic BCL500i series Technical Description

Hide thumbs Also See for BCL500i series:
Table of Contents

Advertisement

Commissioning and configuration
10.12.7 Module 72 – Switching input/output SWIO3
Parameters
Parameter
Function
DC bias level
Reserved
Start-up delay
Switch-on
time
Switch-on
function 1
Switch-on
function 2
Switch-off
function 1
Switch-off
function 2
Comparative
value
(Event Coun-
ter)
Compare
mode
(Event Coun-
ter)
Table 10.50:
162
Description
This parameter defines
whether I/O 3 functions as an
input or as an output.
Mode of operation for configuration as an output
The parameter defines the DC
bias level of the switching out-
put and, thus, simultaneously
whether the output is low-
active (0) or high-active (1).
Free
With this parameter, the output
pulse may be delayed by a set
time period.
The parameter defines the
switch-on time period for the
switching output. If the value is
0, the signal is static.
This parameter specifies an
event which can set the switch-
ing output.
This parameter specifies an
event which can set the switch-
ing output.
Switch-on function 1 and
switch-on function 2 are OR
linked.
This parameter specifies an
event which can reset the
switching output.
This parameter specifies an
event which can reset the
switching output.
Switch-off function 1 and
switch-off function 2 are OR
linked.
If the number of activation
events of the selected switch-
on function reaches this com-
parative value, the switching
output is activated. A deactiva-
tion event of the selected
switch-off function resets the
counter.
Specifies whether the switch-
ing output switches only on
parity (once) or also in the
event of greater or equal to
(multiple times) after the com-
parative value is reached.
Parameters for module 72 – Input/Output 3
Addr.
Data type
0.0
Bit
0.1
Bit
0.2 ... 0.7
1
UNSIGNED16
3
UNSIGNED16
5
UNSIGNED8
6
UNSIGNED8
7
UNSIGNED8
8
UNSIGNED8
9
UNSIGNED16
11
UNSIGNED8
BCL 504
i
Value range
Default
0: Input
0
1: Output
0: LOW (0V)
0
1: HIGH (+Ub)
0 ... 65535
0
0 ... 1300
400
cf. "Switch-on/
switch-off
0
functions"
on page 157
cf. "Switch-on/
switch-off
0
functions"
on page 157
cf. "Switch-on/
switch-off
0
functions"
on page 157
cf. "Switch-on/
switch-off
0
functions"
on page 157
0..65535
0
0: SWOUT
switches
once
1: SWOUT
0
switches
several
times
Leuze electronic
Unit
-
-
ms
ms
-
-
-
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcl504i

Table of Contents