Communication with the control

Creating the connection
An Ethernet cable is needed to connect the control and PG/PC. The following Ethernet
interfaces are available on the control:
● Connection via X127 (behind the flap on the front):
● Connection via X130 (at the back):
1.5.1

How to communicate with the control using the Programming Tool

Setting up the communications interface in the PLC Programming Tool
Proceed as follows to set up the network connection in the PLC Programming Tool:
1. Start the PLC Programming Tool via the following link or via the "Start" menu:
2. In the navigation bar, click the "Communication" icon or select "View" → "Communication"
3. In the left column, under "Communications parameters" enter 192.168.215.1as the IP
4. Double-click the "TCP/IP" icon at the top right.
Turning and Milling
Commissioning Manual, 02/2012, 6FC5397-3DP40-3BA0
Cable type: Crossed Ethernet cable
At interface X127, the control is preset as a DHCP server, delivering the IP
address192.168.215.1 for a direct connection (peer-to-peer connection).
Cable type: Uncrossed Ethernet cable
The interface X130 is the connection to the company network. The IP address that the
PG/PC receives here as a DHCP client is determined by the DHCP server from the
company network or fixed IP address is entered manually.
from the menu.
address for X127.
Scope of delivery and requirements
1.5 Communication with the control