Replacing a drive component later
If a drive component is replaced by a component with a different order number, e.g. a more
powerful module, after the first commissioning, observe the following sequence:
1. Select "Drive unit" → "Topology" → "Change".
2. Select the module and select "Deactivate drive object".
3. Replace the module in the cabinet.
4. Select the module and select "Activate drive object".
5. Update the drive data in the commissioning archive with the new configuration data.
5.1.7
Example: This is how you configure a drive object
Initial state
The following drive objects (DO) are displayed in the "Drive startup" overview:
Drive commissioning
Turning and Milling
Commissioning Manual, 02/2012, 6FC5397-3DP40-3BA0
The configuration data of the new module is read in.
Commissioning the drive
5.1 Configuring the drive
117