Siemens SINUMERIK 828D Commissioning Manual page 343

Turning and milling, valid for cnc software version 4.5
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Parameter
Protocol:
Transmission:
Baud rate:
Archive format:
Interface:
Parity:
Stop bits:
Data bits:
Xon (only for setting Xon/Xoff)
Xoff (only for setting Xon/Xoff)
End of transmission (hex)
Time monitoring (sec)
Deactivating V24
The following machine data should be set to deactivate the interface for data exchange:
● MD51233 $MNS_ENABLE_GSM_MODEM = 0 (Voreinstellung)
● MD51233 $MNS_ENABLE_GSM_MODEM = 1
Turning and Milling
Commissioning Manual, 02/2012, 6FC5397-3DP40-3BA0
The V24 interface is enabled for data transfer.
The softkeys for data transfer are then no longer displayed.
The GSM modem is activated using this setting.
10.6 Parameterizing the serial interface
Permissible values
RTS/CTS (default setting)
Xon/Xoff
normal
backed up (default setting)
19200 (default setting)
300 ... 19200 max.
Punched tape
Binary format (PC format) → only with RTS/CTS protocol
COM1
None (default setting)
Even
Odd
1 (default setting)
2
5 bits
6 bits
7 bits
8 bits (default setting)
11
13
1a
4
Easy Archive
343

Advertisement

Table of Contents
loading

Table of Contents