Example Configuration: Indirect Activation Via The Plc; Task; Procedure - Leuze electronic BCL500i series Technical Description

Hide thumbs Also See for BCL500i series:
Table of Contents

Advertisement

10.16 Example configuration: Indirect activation via the PLC

10.16.1 Task

• Reading of a 15-digit Code 128
• Indirect activation of the BCL 504
Code sample
Code 128, 15 digits
Profibus Inside

10.16.2 Procedure

Hardware, connections
The following connections must have been established:
• Voltage supply (PWR)
• PROFIBUS In
• PROFIBUS termination
Required modules
Include the following modules in your project:
• Module 10 – Activations
• Module 24 – Decoding result 16 bytes
Parameter settings
No parameters need to be set separately. The standard parameter set provides all required
functions.
Leuze electronic
Commissioning and configuration
i
via the PLC
BCL 504
i
179