Setting The Device Address On The Display - Leuze electronic BCL500i series Technical Description

Hide thumbs Also See for BCL500i series:
Table of Contents

Advertisement

Fast commissioning / operating principle
3.4.1

Setting the device address on the display

The display of the BCL 504
address. The PROFIBUS address is set here, i.e. the respective station number of the
network device.
Notice!
The address setting can only be performed via the display if parameter enabling is active.
Information on this topic can be found in chapter "Parameter enabling" on page 93.
The set address must be > ≥0 and < 126. Each network device is thereby automatically
informed that it is a slave on the PROFIBUS with its specific address and that it is initialised
and queried by the PLC.
The PROFIBUS permits an address range from 0 to 126. Address 126 must not be used for
data communication. It may only be used temporarily for commissioning. The default
address is 126.
The address must be assigned individually for each barcode reader of type BCL 504
can be performed by making entries on the display or with the webConfig tool.
Notice!
The BCL
504i
To set the address via the display, proceed as follows:
In the main menu, use the
button
to activate the Parameter menu. The following screen appears:
Parameter
Parameter handling
Decoder table
Digital SWIO
PROFIBUS
PROFIBUS
o PROFIBUS address
PROFIBUS address
12|
<-|0123456789
Standard ----- Unit
126
|
18
i
possesses an important function for setting the PROFIBUS
does not permit address assignment via the PROFIBUS!
buttons to select the Parameter menu and use the enter
1
In the Parameter menu, use the
PROFIBUS menu item.
Press the enter button to enter the PROFIBUS menu.
Press the enter button again to enter the menu for setting
the PROFIBUS address.
Use the
BUS address. An accidental, incorrect entry can be cor-
save
rected by selecting
Then use the
|
set PROFIBUS address by pressing
and
buttons to set the desired PROFI-
and then pressing
<-|
buttons to select save and save the
BCL 504
i
i
; this
buttons to select the
.
.
Leuze electronic

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcl504i

Table of Contents