Pre-Infusion or Pre-Brewing
Group Dose
Settings
Pre-Inf
Settings
Display
Press the T3 button
5
Pre-Inf
WITHOUT PUMP
WITHOUT PUMP
6
Press T1
Pre-Inf Settings
Exit
programming.
7
Press T1
Press T2
8
G1
MODBAR
G2
█
█
163Puls
0Puls
espresso machine.
Description
• This parameter allows the operator to
program the time of pre-brewing of
water with the coffee.
• The time (in seconds) for which the
brewing valve is open during the pre-
brewing cycle and the time (in seconds)
for which the brewing valve is closed
during the pre-brewing cycle; during
this time the pump is active. Once the
pre-brewing cycle is over, the normal
Operating Procedure
to access the menu, then navigate using T1
WITH PUMP
and
, press the T3 button
or T2
until the display shows the exit menu, press the T3 button
or T2
to continue with the programming of the other parameters.
and T3
at the same time to exit the programming mode and return to the normal use of the
"Barista" Programming
brewing cycle will continue until the
end.
• For an espresso machine composed of
two groups, they are identified as Group
1 and Group 2.
and T2
to choose between
to confirm the option.
to return to the "Barista"