"Barista" Programming
Pre-Infusion or Pre-Brewing
Group Dose
Settings
Pre-Inf
Settings
Display
When the espresso machine is turned on, press and hold the T3 button
1
G1
MODBAR
G2
█
█
163Puls
0Puls
After about 5 seconds the following screen is displayed.
2
Group Dose
Move between the parameters using the buttons T1
Settings
3
Pre-Inf
Press the T3 button
Settings
Press T1
4
By pressing the T3 button
Group 1 Pre-Inf
2s Wet 0s Hold
that you want to set, press T3
To set the preinfusion time 2 seconds minimum.
60
Description
• This parameter allows the operator to
program the time of pre-brewing of
water with the coffee. Each group can
have a different programming.
• Pre-brewing has only two values to be
adjusted for each group. The time (in
seconds) for which the brewing valve
is open during the pre-brewing cycle
and the time (in seconds) for which
the brewing valve is closed during the
Operating Procedure
to enter the menu.
or T2
to select the group whose parameters you want to set.
the first value will blink. Use the buttons T1
to confirm. Repeat this operation to set the second value.
pre-brewing cycle; during this time the
pump is active. Once the pre-brewing
cycle is over, the normal brewing cycle
will continue until the end.
• For an espresso machine composed of
two groups, they are identified as Group
1 and Group 2.
to access the "Barista" programming.
or T2
until the display shows:
and T2
to reach the value