Rosemount Model 3051 Transmitter with F
Vibration Effect
Power Supply Effect
RFI Effects
Transient Protection
(Option Code T1)
FUNCTIONAL
SPECIFICATIONS
Range and Sensor Limits
A-4
TM
fieldbus Protocol
OUNDATION
Model 3051H
Zero shifts up to ±5 inH
can be calibrated out (no span effect)
All Models
Measurement effect due to vibrations is insignificant except at
resonance frequencies. At resonance frequencies, vibration effect is less
than ±0.1% of URL per g when tested between 15 and 2000 Hz in any
axis relative to pipe-mounted process conditions.
All Models
Less than ±0.005% of calibrated span per volt
All Models
±0.1% of span from 20 to 1000 MHz and for field strength up to 30 V/m
All Models
Meets IEEE Standard 587, Category B
1 kV crest (10 × 1 000 microseconds)
3 kV crest (8 × 20 microseconds)
6 kV crest (1,2 × 50 microseconds)
Meets IEEE Standard 472, Surge Withstand Capability
SWC 2,5 kV crest, 1 MHz wave form
General Specifications
Response Time
Peak Surge Current
Peak Transient Voltage
Loop Impedance
Applicable Standards
NOTE:
Calibrations at 68 °F (20 °C) per ASME Z210.1 (ANSI)
See Table 1 for the Model 3051CD, 3051CG, 3051L, and 3051H Range
and Sensor Limits.
O (127 mmH
O)
2
2
< 1 nanosecond
5000 amps to housing
100 V dc
< 25 ohms
IEC 801-4, IEC 801-5