Setup

Linking the Reader

Link Datalogic Devices to Base
Before configuring the interface it is necessary to link the handheld with the
base.
To link the handheld and the base simply put it into the base. If the reader was
previously linked to another base, you must first scan the Unlink bar code
before re-linking to the new base.

Link Scanner as Serial Device to a Bluetooth Host

Use this procedure to let the scanner communicate with a Bluetooth host using
the Bluetooth Serial Port Profile (SPP).
1. If using a Bluetooth adapter on the host device, install any driver provided
2. Scan the Link to Host in SPP mode label below to make the scanner visible
3. Use the Bluetooth manager of the host device to "Discover new devices"
4. Use an RS-232 terminal program to see incoming data on the port desig-
28
with the adapter.
to the host device.
and select "GBT4500...". If you receive an error message, it may be neces-
sary to change the security settings on either the host device or the scan-
ner.
nated by the Bluetooth manager of the host device.