Enter/Exit Programming Mode

Datalogic 2 of 5 Length Control

This feature specifies either variable length decoding or fixed length decoding
for the Datalogic 2 of 5 symbology.
Variable Length:
may be set.
Fixed Length:
DEFAULT
Datalogic 2 of 5 Length Control = Fixed Length

Datalogic 2 of 5 Set Length 1

This feature specifies one of the bar code lengths for
Control on page
on page 171
Mode. The length includes the bar code's data characters only.
The length can be set from 2 to 50 characters in increments of two. See
Length 1"
$CD2L1
Select Datalogic 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
176
For variable length decoding, a minimum and maximum length
For fixed length decoding, two different lengths may be set.
176. Length 1 is the minimum label length if in
Mode, or the first fixed length if in
on page 302 for more detailed programming instructions.
06 = Length 1 is 6 Characters
DEFAULT
Datalogic 2 of 5 Length Control = Variable Length
Datalogic 2 of 5 Length
Fixed Length on page 171
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from
the Alphanumeric characters in
pad
representing your desired character(s). End by
scanning the ENTER/EXIT bar code again.
~
CANCEL
Gryphon™ I GD/GBT/GM4500
Datalogic 2 of 5
Variable Length
"Set