Danfoss MCO 305 Operating Instructions Manual page 15

Hide thumbs Also See for MCO 305:
Table of Contents

Advertisement

MCO 305 Operating Instructions
Terminal overview
Terminal
Terminal
block
number
1
2
3
4
5
6
X55
7
8
9
10
11
12
Terminal
Terminal
block
number
1
2
3
4
5
6
X56
7
8
9
10
11
12
__ How to Install __
Descriptive Name
Encoder 2 (Feedback)
+24V Supply
+8V Supply
+5V Supply
GND
A
A not
B
B not
Z / Clock
Z not / Clock not
DATA
DATA not
Descriptive Name
Encoder 1 (Master)
+24V Supply
N/A (not available)
+5V Supply
GND
A
A not
B
B not
Z / Clock
Z not / Clock not
DATA
DATA not
MG.33.K2.02 – VLT is a registered Danfoss trademark
Terminal
Terminal
Descriptive Name
block
number
Digital inputs
1
Digital Input
2
Digital Input
3
Digital Input
4
Digital Input
5
Digital Input
X57
6
Digital Input
7
Digital Input
8
Digital Input
9
Digital Input
10
Terminal
Terminal
Descriptive Name
block
number
Supply
1
+24V Supply
X58
2
GND
Terminal
Terminal
Descriptive Name
block
number
Digital outputs
1
Digital Output/Input
2
Digital Output/Input
3
Digital Output
4
Digital Output
X59
5
Digital Output
6
Digital Output
7
Digital Output
8
Digital Output
Digital Input
15

Advertisement

Table of Contents
loading

Table of Contents