MCO 305 Operating Instructions
__ How to Install __
Electrical Installation
All control cables must be screened and the cable screen must be connected to earth at both ends. It is
very important to use the correct cable for encoders to avoid noise problems, always follow the prescrip-
tions of the encoder supplier. See also FC 300 Design Guide (MG.33.AX.XX) for more information regarding
EMC correct cable installation.
MCO 305 Control Terminals
Frame size A2 and A3:
All MCO 305 terminals are located behind the C-
option terminal cover, see illustration.
Frame size A5, B1 and B2:
All MCO 305 terminals are located next to the
FC 300 control card. Remove the front cover to get
access, see illustration.
13
MG.33.K2.02 – VLT is a registered Danfoss trademark