MCO 305 Operating Instructions

How to Install

How to Get Started

Please consult the FC 300 Operating Instructions (MG.AX-XX) for correct installation of FC 300, this
instruction covers installation of MCO 305.
The installation procedure depends on whether the MCO 305 was delivered as an option for upgrading an
existing FC 300 or if it was preinstalled before delivery. Skip the next chapter (Mechanical installation) if the
MCO 305 was preinstalled:
Initialization to Default Settings
Initialize the frequency converter to default setting in two ways:
Recommended initialization (via par. 14-22):
1. Select par. 14-22
2. Press [OK]
3. Select "Initialization"
4. Press [OK]
5. Cut off the mains supply and wait until the
displays turns off.
6. Reconnect the mains supply – the frequency
converter is now reset.
NB!
MCO 305 programs and arrays are not
affected.
MG.33.K2.02 – VLT is a registered Danfoss trademark
Par. 14-22 initializes all except:
14-50
RFI 1
8-30
Protocol
8-31
Address
8-32
Baud Rate
8-35
Minimum Response Delay
8-36
Maximum Response Delay
8-37
Max Inter-char Delay
15-00 to 15-05
Operating Data
15-20 to 15-22
Historic log
15-30 to 15-32
Fault log