MCO 305 Operating Instructions
Error 171
Array too small
An attempt was made to describe an array element
that is located outside of the defined array limits.
Cause might be an error in the APOSS program.
Array sizing does not agree with the space required
(e.g. due to an incorrectly programmed loop).
Or the array is too small for the number of test
drives triggered by TESTSTART.
Check loop variables.
Error 179
Waitndx timeout
The command WAITNDX was executed and the
timeout listed was exceeded.
The timeout is probably too short or the index
impulse could not found (see also Error 109).
Error 184
Too many ontime
Too many interrupts (ON TIME or ON PERIOD
commands) were used within the program.
A maximum of 12 of these ON TIME and/or ON
PERIOD commands are allowed within one
program.
Error 187
Out of memory
No more space for variables.
When the APOSS program is started the space for
the necessary variables is reserved dynamically.
This space is now no longer available.
You may have selected a maximum number of
variables which is too high. Reduce the maximum
number in Settings
Compiler (Standard = 92).
Or the memory available is occupied with programs
or arrays. Delete the programs or delete both the
programs and arrays, i.e. by deleting the entire
memory.
NB!:
Remember to follow the recommendations
concerning saving programs and
parameters before deleting the EEPROM.
__ Troubleshooting __
Error 190
Memory locked
The program memory is write-protected and
cannot be altered.
This means that auto recognition can neither be set
nor deleted and programs can neither be saved nor
deleted. Equally,
delete will not be executed.
Error 191
Illegal cam array
An incorrect or old array is defined in the DIM
instruction for SETCURVE.
An old array may exist if the CNF file with all para-
meters and arrays has not been loaded into the
CAM-Editor.
An incorrect array could be caused by the
following:
Error 192
Encoder error
Error from encoder monitoring: open or short
circuit in accordance with the displayed LED.
Error 199
Internal MCO fault
If such an error should occur, please contact your
dealer and report the error number displayed to
the technical service department.
MG.33.K2.02 – VLT is a registered Danfoss trademark
RAM save and
It was not created by the curve editor.
Previous version of a curve editor. Such an array
must first be converted by the current CAM-
Editor (
load and save).
Or the order of the arrays in the DIM instruction
does not match the order in the cnf file. Refer to
the number of the array in the title bar of the
CAM-Editor in this respect.
NB!:
An error will be indicated even if no
encoder is connected.
EEPROM