MCO 305 Operating Instructions
Manual initialization
1.
Disconnect from mains and wait until the
display turns off.
2.
Press [Status] – [Main Menu] – [OK] at the
same time:
3.
Reconnect mains supply while pressing the keys.
4.
Release the keys after 5 s.
5.
The frequency converter is now programmed
according to default settings.
NB!:
When you carry out manual initialization, you also reset serial communication and fault log
settings.
And all MCO 305 programs and arrays are deleted!

System Overview

Mechanical Installation
(Only relevant if the MCO 305 is delivered as option for upgrading an existing FC300)
Frame size A2 and A3
10
__ How to Install __
MG.33.K2.02 – VLT is a registered Danfoss trademark
This method initializes all except:
15-00
Operating Hours
15-03
Power-up's
15-04
Over temp's
15-05
Over volt's