Other Additions For Diagnostics Transducer Blocks - Emerson Micro Motion 2700 Configuration And Use Manual

With foundation fieldbus
Hide thumbs Also See for Micro Motion 2700:
Table of Contents

Advertisement

Transducer blocks and views
Table A-15:
Meter fingerprinting for diagnostic transducer blocks
Index and name
#49
MFP_TV_MAX
#50
MFP_TV_MIN
A.4.7

Other additions for diagnostics transducer blocks

Table A-16:
Other additions for diagnostics transducer blocks
Index and name
#51
DIAG_FEATURE_KEY
#52
SYS_PowerOnTimeSec
#53
SNS_InputVoltage
178
Description
Transmitter variable, maximum
(since last statistics reset)
Msg type = VAR
Data type = FLOAT (4)
Store = Dynamic
Access = Read only
Available in Release 3.0
Transmitter variable, minimum
(since last statistics reset)
Msg type = VAR
Data type = FLOAT (4)
Store = Dynamic
Access = Read only
Available in Release 3.0
Description
Enabled features
Msg type = STR
Data type = BIT STRING (2)
Store = Static
Access = Read only
Available in Release 4.0
Power on time (seconds since last
reset)
Msg type = VAR
Data type = Unsigned32 (4)
Store = Dynamic
Access = Read only
Available in Release 4.0
Input voltage (volts)
Msg type = VAR
Data type = FLOAT (4)
Store = Dynamic
Access = Read only
Available in Release 4.0
Micro Motion Model 2700 Transmitters with FOUNDATION Fieldbus
(continued)
List of values
List of values
0x0000 = standard
0x0800 = Meter verification
0x0008 = Enhhanced density
0x0010 = API
HW
700
700
HW
700
800
CDM
FDM
FVM
700
800
CDM
FDM
FVM
700
800
CDM
FDM
FVM