Transducer blocks and views
Table A-26:
Process variables for density viscosity transducer blocks
Index and name
#53
DEN_FixedVelocity
#54
DEN_VelocityUnits
#55
DEN_VelocityCutoff
#56
DEN_VelocityHiLim
#57
DEN_VelocityLoLim
#58
DEN_VelocitySpan
#59
DEN_VelocityDamping
252
Description
Fixed flow velocity value (m/sec)
Msg type = VAR
Data type = DS65
Store = Dynamic/20
Access = Read only
Available in Release 8.0
Flow velocity units
Msg type = VAR
Data type = Unsigned16 (2)
Store = Static
Access = R/W (OOS)
Available in Release 8.0
Flow velocity units
Msg type = VAR
Data type = Float (4)
Store = Static
Access = R/W (OOS)
Available in Release 8.0
Flow velocity high limit
Msg type = VAR
Data type = Float (4)
Store = Static
Access = Read only
Available in Release 8.0
Flow velocity low limit
Msg type = VAR
Data type = Float (4)
Store = Static
Access = Read only
Available in Release 8.0
Flow velocity span
Msg type = VAR
Data type = Float (4)
Store = Static
Access = Read only
Available in Release 8.0
Flow velocity damping
Msg type = VAR
Data type = Float (4)
Store = Static
Access = R/W (OOS)
Available in Release 8.0
Micro Motion Model 2700 Transmitters with FOUNDATION Fieldbus
(continued)
List of values
HW
CDM
1061 = Meters/Sec-
CDM
ond
1067 = Feet/Second
CDM
CDM
CDM
CDM
CDM