Table A-4:
Process variables for measurement transducer blocks
Index and name
#41
FLOW_DIRECTION
#42
HIGH_MASS_LIMIT
#43
HIGH_TEMP_LIMIT
#44
HIGH_DENSITY_LIMIT
#45
HIGH_VOLUME_LIMIT
#46
LOW_MASS_LIMIT
#47
LOW_TEMP_LIMIT
Configuration and Use Manual
Description
Flow direction
Msg type = ENUM
Data type = Unsigned16 (2)
Store = Static
Access = RW in any mode
Available in Release 1.0
High mass flow limit of sensor
Msg type = VAR
Data type = FLOAT (4)
Store = Static
Access = Read only
Available in Release 1.0
High temperature limit of sensor
Msg type = VAR
Data type = FLOAT (4)
Store = Static
Access = Read only
Available in Release 1.0
High density limit of sensor in g/cc
Msg type = VAR
Data type = FLOAT (4)
Store = Static
Access = Read only
Available in Release 1.0
High volume flow limit of sensor
Msg type = VAR
Data type = FLOAT (4)
Store = Static
Access = Read only
Available in Release 1.0
Low mass flow limit of sensor
Msg type = VAR
Data type = FLOAT (4)
Store = Static
Access = Read only
Available in Release 1.0
Low temperature limit of sensor
Msg type = VAR
Data type = FLOAT (4)
Store = Static
Access = Read only
Available in Release 1.0
(continued)
List of values
0 = Forward Only
1 = Reverse Only
2 = Bi-Directional
3 = Absolute Value
4 = Negate/Forward Only
5 = Negate/Bi-Dir
—
—
—
—
—
—
Transducer blocks and views
HW
700
800
CDM
700
800
700
800
CDM
FDM
FVM
700
800
CDM
FDM
FVM
700
800
700
800
700
800
CDM
FDM
FVM
141