FSW3524E 00: Cust Settings
Eqiz Support
Appears only when
Eqiz Voltage
Equalize support is Enabled.
Bulk Voltage
Bulk Termination Voltage
Absorb Voltage
Float Voltage
BattTempComp
Figure 30 Custom Settings Menu Screen
54
[Enabled]
[32.0V]
[22.4V]
[22.0V]
[28.8V]
[25.0V]
[-54mV/C]
Follow procedures on "To select and change a
configurable setting:" on page 38 to change the settings.
Table 12 Setting Defaults and Ranges
Model
Freedom SW 230V
Item
Default
Min
Eqlz Support
Enabled
Eqlz Voltage
31.0V
27.0V
Bulk Voltage
28.8V
22.4V
Bulk
28.4V
22.0V
Termination
Voltage
Absorb Voltage
28.8V
24.0V
Float Voltage
27.0V
22.0V
Batt Temp Comp
54-mV
0-mV
The Custom Battery Settings menu can be viewed if Custom is
selected as the Batt Type. This menu allows you to adjust charging
and equalization voltage for batteries with specifications that fall
outside the default settings for the battery types the Freedom SW
230V offers. You can also adjust the temperature compensation
constant for the battery temperature sensor on this menu.
IMPORTANT:
All settings for configuring a custom battery type are based
on the default settings for a flooded battery type.
Max
Enabled,
Disabled
32.0V
32.0V
31.6V
32.0V
32.0V
90-mV
Freedom SW 230V Owner's Guide