[T7]
6 x 525-690 V AC – high overload
Output current
Type
code
(3 x 525-550 V)
Inter. I
FC-302
Con. I
(60 s)
N
P355
395
593
P450
429
644
P500
523
785
P560
596
894
P630
659
989
P710
763
1145
P800
889
1334
P900
988
1482
P1M0
1108
1662
P1M2
1317
1976
[T7]
6 x 525-690 V AC – normal overload
Output current
Type
code
(3 x 525-550 V)
Inter. I
FC-302
Con. I
(60 s)
N
P355
470
517
P450
523
575
P500
596
656
P560
630
693
P630
763
839
P710
889
978
P800
988
1087
P900
1108
1219
P1M0
1317
1449
P1M2
1479
1627
Dimensions enclosure size F
Enclosure size
Protection rating [IEC/UL]
Height
[mm]
Width
Depth
[kg]
Weight
Height
[in]
Width
Depth
Weight
[lb]
40
Danfoss Drives · DKDD.PB.302.A8.02 | Content |
High overload (150% 1 min/10 min)
(3 x 551-690 V)
Inter. I
Con. I
kW @ 690 V
MAX
MAX
(60 s)
N
380
570
410
615
500
750
570
855
630
945
730
1095
850
1275
945
1418
1060
1590
1260
1890
Normal overload (110% 1 min/10 min)
(3 x 551-690 V)
Inter. I
Con. I
kW @ 690 V
MAX
MAX
(60 s)
N
450
495
500
550
570
627
630
693
730
803
850
935
945
1040
1060
1166
1260
1386
1415
1557
F8
2204.0
800.0
606.0
447.0
86.8
31.5
23.9
985.5
Conti-
Typical shaft
nuous
output power
input
current
Hp @ 575 V
[A]
355
400
381
400
400
413
500
500
504
560
600
574
630
650
642
710
750
743
800
950
866
900
1050
962
1000
1150
1079
1200
1350
1282
Conti-
Typical shaft
nuous
output power
input
current
Hp @ 575 V
[A]
450
450
453
500
500
504
560
600
574
630
650
607
710
750
743
800
950
866
900
1050
962
1000
1150
1079
1200
1350
1282
1400
1550
1440
VLT® AutomationDrive
F9
F10
IP21 / Type 1
IP54 / Type 12
2204.0
2204.0
1400.0
1600.0
606.0
606.0
669.0
893.0
86.8
86.8
55.2
63.0
23.9
23.9
1474.9
1968.8
Enclosure size
Esti-
Protection rating [IEC/UL]
mated
power
IP21/Type 1
loss
AC
+
[W]
drive
options
4589
F8
F9
4970
F8
F9
6707
F8
F9
7633
F8
F9
8388
F10
F11
9537
F10
F11
11291
F10
F11
12524
F12
F13
13801
F12
F13
16719
F12
F13
Enclosure size
Esti-
Protection rating [IEC/UL]
mated
power
IP21/Type 1
loss
AC
+
[W]
drive
options
5529
F8
F9
6239
F8
F9
7653
F8
F9
8495
F8
F9
9863
F10
F11
11304
F10
F11
12798
F10
F11
13801
F12
F13
16821
F12
F13
F12
F13
19247
F11
F12
2204.0
2204.0
2400.0
2000.0
606.0
606.0
1116.0
1037.0
86.8
86.8
94.5
78.8
23.9
23.9
2460.4
2286.4
IP54/Type 12
AC
+
drive
options
F8
F9
F8
F9
F8
F9
F8
F9
F10
F11
F10
F11
F10
F11
F12
F13
F12
F13
F12
F13
IP54/Type 12
AC
+
drive
options
F8
F9
F8
F9
F8
F9
F8
F9
F10
F11
F10
F11
F10
F11
F12
F13
F12
F13
F12
F13
F13
2204.0
2800.0
606.0
1259.0
86.8
110.2
23.9
2775.7
Need help?