[1]
[2]
[3]
FC-
–
–
[8] PCB coating – IEC 721-3-3 (character 20)
X
Standard coated PCB Class 3C2
C
Coated PCB Class 3C3
R
Coated PCB Class 3C3 + ruggedized
[9] Mains input (character 21)
X
No mains option
7
Fuses
Fuses and load sharing terminals
A
(enclosure sizes D/IP20 and F3, F4, F9, F11,
F14, F18 only)
Load sharing terminals
D
(enclosure sizes D/IP20 and F3, F4, F9, F11, F14,
F18 only)
Mains disconnect + fuse
3
(enclosure sizes D, E and F3, F4, F9, F11, F14, F18)
4
Mains contactor + fuse (enclosure size D)
Mains disconnect, fuse and load sharing
5
(Not available for enclosure size F18)
Mains disconnect + contactor + fuse
E
(enclosure sizes D, E and F3, F4, F9, F11, F14, F18)
Circuit breaker + fuse
J
(enclosure sizes D, E and F3, F4, F9, F11, F14, F18)
Mains circuit breaker, contactor and fuses
F
(enclosure sizes F3, F4, F9, F11, F14, F18)
Mains disconnect, contactor, load sharing
G
terminals and fuses
(enclosure sizes F3, F4, F9, F11, F14, F18)
Mains circuit breaker, contactor, load sharing
H
terminals and fuses
(enclosure sizes F3, F4, F9, F11, F14, F18)
Mains circuit breaker, load share and fuses
K
(enclosure sizes F3, F4, F9, F11, F14, F18)
Cable connection cabinet
T
(enclosure size D5h/D7h only)
Cable connection cabinet and fuse
W
(enclosure size D5h/D7h only)
[10] Hardware option A (character 22)
X
Standard cable entries
Enclosure sizes F1, F2, F3, F4, F10, F11, F12, F13, F18
E
30 A fuse protected power terminals
30 A fuse protected power terminals and
F
2.5-4 A manual motor starter
30 A fuse protected power terminals and
G
4-6.3 A manual motor starter
30 A fuse protected power terminals and
H
6.3-10 A manual motor starter
30 A fuse protected power terminals and
J
10-16 A manual motor starter
K
Two 2.5-4 A manual motor starters
L
Two 4-6.3 A manual motor starters
M
Two 6.3-10 A manual motor starters
N
Two 10-16 A manual motor starters
[4]
[5]
[6]
[7]
–
–
–
–
–
[11] Hardware option B (character 23)
X
No adaptation
Heat sink access panel
Q
(enclosure size D and E only)
Enclosure sizes F1, F2, F3, F4, F10, F11, F12, F13, F18
5 A 24 V supply (customer use) and
G
external temperature monitoring
H
5 A 24 V supply (customer use)
J
External temperature monitoring
K
Common motor terminals
L
5 A 24 V supply + common motor terminals
External temperature monitoring + common
M
motor terminals
5 A 24 V supply + external temperature
N
monitoring + common motor terminals
[12] Special version (character 24-27)
SXXX Latest released standard software
S067
Integrated Motion Control
[13] LCP language (character 28)
Standard language package including
X
English, German, French, Spanish, Danish,
Italian, Finnish and others
Contact factory for other language options
[14] A-options: Fieldbus (character 29-30)
AX
No option
A0
VLT® PROFIBUS DP MCA 101
A4
VLT® DeviceNet MCA 104
A6
VLT® CANopen MCA 105
AT
VLT® 3000 PROFIBUS Converter MCA 113
AU
VLT® 5000 PROFIBUS Converter MCA 114
AL
VLT® PROFINET MCA 120
AN
VLT® EtherNet/IP MCA 121
AQ
VLT® Modbus TCP MCA 122
AY
VLT® POWERLINK MCA 123
A8
VLT® EtherCAT MCA 124
AV
VLT® 5000 DeviceNet Converter MCA 194
[15] B-options (character 31-32)
BX
No application option
BK
VLT® General Purpose MCB 101
BR
VLT® Encoder Input MCB 102
BU
VLT® Resolver Input MCB 103
BP
VLT® Relay Option MCB 105
BZ
VLT® Safety PLC I/O MCB 108
B2
VLT® PTC Thermistor Card MCB 112
B4
VLT® Sensor Input Card MCB 114
B6
VLT® Safety Option MCB 150 TTL
B7
VLT® Safety Option MCB 151 HTL
[8]
[9]
[10]
[11]
[12]
[13]
–
–
–
–
–
| Content | Danfoss Drives · DKDD.PB.302.A8.02
[14]
[15]
[16]
[17]
[18]
–
–
– CX –
– XX –
B8
VLT® Safety Option MCB 152 PROFIsafe STO
[16] C0-option (character 33-34)
CX
No option
C4
VLT® Motion Control MCO 305
[17] C1-option (character 35)
X
No option
R
VLT® Extended Relay Card MCB 113
[18] C1-option software (character 36-37)
No software option
Note: C4 option in [16] selected with no motion
XX
software in [18] will require programming by
qualified individual
VLT® Synchronizing Controller MCO 350
10
(must select C4 in position [16])
VLT® Positioning Controller MCO 351
11
(must select C4 in position [16])
[19] Control Power Back-up Input (character 38-39)
DX
No DC input installed
D0
VLT® 24 V DC Supply Option MCB 107
D1
VLT® Real-time Clock Option MCB 117
Please beware that not all combinations are possible.
Find help configuring your drive with the online
configurator found under:
driveconfig.danfoss.com
[19]
43
Need help?
Do you have a question about the VLT AutomationDrive FC 300 Series and is the answer not in the manual?
Questions and answers