LCR-800 Series User Manual
Accuracy:
R, L, C: 0.05% (Basic)
D, Q: 0.0005 (Basic)
*LCR-816/826/827/829 is one fold less accuracy than LCR-817/819.
(LCR-816/826: 0.2%, LCR-827/829: 0.1%, LCR-817/819: 0.05%)
Test Frequency:
There are 503 test frequencies between 12Hz and 100kHz that can be selected
by using keypad for LCR-819/829. The frequency range of LCR-817/827
covers from 12Hz to 10kHz, LCR-816/826 covers from 100Hz to 2kHz.
Measurement Displays:
The measured results can be shown on the LCD monitor in four ways:
: The measured quantities of R/Q, C/D, C/R, or L/Q.
1. VALUE
*The resolution of primary display (L, C, or R) is five digits.
*The resolution of secondary display (D, Q or R with C) is four
digits.
: The LCR difference is similar to the DELTA% except that the
2. DELTA
deviation is shown in suitable units (ohms, henries, etc.)
3. DELTA % : The DELTA% shows the percent deviation of the measured L,
C, or R value from a saved NOMINAL VALUE. The sign of
deviation is indicated.
Measurement Speed (LCR-816/817/819):
SLOW
896ms
:
MEDI
286ms
:
FAST
135ms
:
*For LCR-826/827/829, please refer to 4-5-10. Handler Interface Timing.
Equivalent Circuit:
The L, C, or R equivalent SERIES or PARALLEL circuit can be selected by
keypad.
+
Please refer to page41~43 for details.
+
+