Danfoss VLT AutomationDrive FC 360 Programming Manual page 38

Profinet
Hide thumbs Also See for VLT AutomationDrive FC 360:
Table of Contents

Advertisement

Parameters
6.5.4 PROFINET-specific Parameter List
Parameter 0-37 Display Text 1
Parameter 8-01 Control Site
Parameter 8-02 Control Source
Parameter 8-03 Control Timeout Time
Parameter 8-04 Control Timeout Function
Parameter 8-07 Diagnosis Trigger
Parameter 8-10 Control Word Profile
Parameter 8-14 Configurable Control Word
CTW
Parameter 8-19 Product Code
6
6
Parameter 8-50 Coasting Select
Parameter 8-51 Quick Stop Select
Parameter 8-52 DC Brake Select
Parameter 8-53 Start Select
Parameter 8-54 Reversing Select
Parameter 8-55 Set-up Select
Parameter 8-56 Preset Reference Select
Parameter 8-57 Profidrive OFF2 Select
Parameter 8-58 Profidrive OFF3 Select
Parameter 8-90 Bus Jog 1 Speed
Parameter 8-91 Bus Jog 2 Speed
Parameter 9-07 Actual Value
Parameter 9-15 PCD Write Configuration
Parameter 9-16 PCD Read Configuration
Parameter 9-22 Telegram Selection
Parameter 9-23 Parameters for Signals
Parameter 9-27 Parameter Edit
Parameter 9-28 Process Control
Parameter 9-53 Profibus Warning Word
Parameter 9-65 Profile Number
Parameter 9-70 Edit Set-up
Parameter 9-71 Profibus Save Data Values
Parameter 9-72 ProfibusDriveReset
Parameter 9-80 Defined Parameters (1)
Parameter 9-81 Defined Parameters (2)
Parameter 9-82 Defined Parameters (3)
Parameter 9-83 Defined Parameters (4)
Parameter 9-84 Defined Parameters (5)
Parameter 9-85 Defined Parameters (6)
Parameter 9-90 Changed Parameters (1)
Parameter 9-91 Changed Parameters (2)
Parameter 9-92 Changed Parameters (3)
Parameter 9-93 Changed Parameters (4)
Parameter 9-94 Changed Parameters (5)
Parameter 12-00 IP Address Assignment
Parameter 12-01 IP Address
Parameter 12-02 Subnet Mask
Parameter 12-03 Default Gateway
Parameter 12-04 DHCP Server
Parameter 12-05 Lease Expires
36
PROFINET
Parameter
0
[0] Dig. & ctrl. word
1
[0] Off
[0] Disable
[0] FC profile
[1] Profile default
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
[3] Logic OR
100 RPM
200 RPM
0 N/A
[100] None
[0]
[1] Enabled
[1] Enable cyclic master
0
0
[9] Active set-up
[0] Off
[0] No action
0
0
0
0
0
0
0
0
0
0
0
[10] DCP
0
0
0
0
Danfoss A/S © 04/2017 All rights reserved.
Default value
2 set-up
1 set-up
All set-ups
All set-ups
1 set-up
1 set-up
1 set-up
All set-ups
All set-ups
1 set-up
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
1 set-up
1 set-up
1 set-up
All set-ups
1 set-up
1 set-up
All set-ups
All set-ups
1 set-up
All set-ups
1 set-up
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
All set-ups
1 set-up
1 set-up
1 set-up
1 set-up
1 set-up
All set-ups
Change during
Conversion
operation
index
TRUE
0
Visible string 21
TRUE
TRUE
TRUE
-1
TRUE
TRUE
TRUE
TRUE
TRUE
0
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
0
TRUE
0
FALSE
0
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
TRUE
0
TRUE
0
TRUE
TRUE
FALSE
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Time diff. w/date
Data type
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint32
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
V2
Oct. string 2
Uint8
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint8
Oct. string 4
Oct. string 4
Oct. string 4
Oct. string 4
MG06G102