Installer Mode Programming
1. Use the u or n keys to highlight a zone you wish to
delete (the display shows an "*" next to zones that
have detectors) and press >.
2. You have the choice of deleting the detector ID or of
defaulting the zone. Press u or n to see each of
these choices.
If you select "Delete Detector ID" then the control
unit "forgets" the ID of the detector, but leaves any
zone programming in place.
If you select "Default zone" then the control unit
"forgets" the ID of the detector and sets all the zone
programming back to default values: Type = Not
Used, no attributes.
3. Press Y to confirm your choice.
To reinstate the detector you must teach the control unit
that detector's identity again.
Edit Zones
You can program each zone's behaviour at any time,
whether or not a wired detector is connected, or the
control unit has learned the identity of a radio detector.
Note: If a wired zone does not have a detector connected
to it then make sure that you set the zone type to
"Not Used". When delivered from the factory the
control unit has all zones set to "Not Used" (unless
you load a Profile during initial start-up).
Name, Type, Attributes, Partitions
To change the name associated with a zone, its type,
attributes or partitions then select Detectors/Devices -
Detectors – Edit Zones. The bottom line of the display starts
at zone 1.
1. Press u or n to show the other zones.
(Hint: You can key in the zone number you wish to
edit, for example:"05" to see zone 05, "02" to see
zone 02, "30" to see zone 30 or "40" to see zone 40.)
Page 10