Cooper Security i-on40 Programming Reference Manual page 41

Hide thumbs Also See for i-on40:
Table of Contents

Advertisement

i-on40
Type:
Panel Battery
Fault (13)
External PSU
Low Volts
(14)
Active when:
The control unit detects a
fault with its backup
battery, OR a zone of type
"External PSU Battery
Fault" has been triggered.
If the alert was caused by
an "External PSU Battery
Fault" zone then the
control unit deactivates the
output when the zone has
been restored and a user
has acknowledges the fault
by entering a valid access
code.
If the alert was caused by
a fault with the control
unit's backup battery then
the control unit deactivates
the output when it detects
a good battery and a user
acknowledges the alert.
Note: To cause the control
unit to check its backup
battery enter and leave the
Installer Menu.
An external power supply
has triggered an External
PSU Low Volts zone.
The control unit deactivates
the output when the zone
has been restored and a
user has acknowledges the
fault by entering a valid
access code.
Installer Mode Programming
Assign to
Partitions?
No
No