Appendix III: Programming a Common
Some commercial premises include two or more separate
areas linked by a common area. You can program the i-
on40 to allow users to set each area independently, and
then set the common area automatically when the last
occupant leaves the premises. The Full Set Link option in
Installer Menu - Partitions provides this feature.
Figure 4 shows a typical example of a commercial
building that could use the "Common Area".
Figure 4. Typical commercial building.
The business using the building is split into Factory and
Office departments. These two sets of users work
different hours. The manager wants each department to
be able to set their own part of the alarm system
separately. The common area including the Foyer,
Kitchen and Toilet should only be armed when there is no
one in the building. This will allow either the Factory or
the Office staff to use those facilities when part of the
alarm system is armed.
Page 101
Area
i-on40
Zone List:
1. Front Door
2. Foyer PIR
3. Loading Bay
Entrance
4. Shutter
5. Loading Bay PIR
6. Factory PIR
7. Factory Fire
Door
8. Kitchen PIR
9. Office Fire Door
10. Office PIR
11. Reception PIR
12. Reception
Entrance