Cooper Security i-on40 Programming Reference Manual page 71

Hide thumbs Also See for i-on40:
Table of Contents

Advertisement

i-on40
Burg Comms Rearm
(This menu appears only if you select "Fast Format" in
Communications - Report Type.) This menu option
determines what the control unit does with the "Burg"
Fast Format channel 3 at the end of the siren run time.
There are two options:
Disabled
The channel stays active until an Installer or user
resets the system.
Enabled
The system rearms Channel 3 once the siren timer
has expired. Once the Channel is rearmed, the
system is ready to report any new alarm. The system
bypasses any detectors that are still triggered.
Notes:
If a Final Exit Zone is triggered, Channel 3 becomes
active at the end of the Programmed Entry time.
21CN FF Ack Time
(This menu appears only if you select "Fast Format" in
Communications - Report Type.)
A PSTN line connected to a BT21CN line (or equivalent)
will take longer to acknowledge a Fast Format
transmission. This option allows you to adjust the length
of time that the control unit waits for the ARC
acknowledgement. You can adjust the acknowledgement
time from a minimum of 400ms up to a maximum of
1200ms in 100ms steps.
Send Tamper as Burg
When using CID reporting this option allows you to
program the control unit to send tampers as alarm.
If you select Disabled, (the default) then the control unit
sends all CID messages as specified in Communications –
ARC Reporting – CID/SIA Events.
If you select Enabled then for full alarm response the
control unit sends tampers as burglary (BA) and sends
Contact ID 130 in place of Contact ID 137.
Installer Mode Programming
Page 67

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the i-on40 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents