11.6. Troubleshooting operation problems
PROBLEM
DRIED LINEN MOISTURE
LEVEL TOO HIGH
INCORRECT DRUM
SPEED
FLAME TOO ORANGE
(GAS VERSION)
THE BURNER CAN NOT
BE IGNITED (GAS
VERSION)
POOR FLAME SPREAD
(GAS VERSION)
DRIED LINEN MOISTURE
LEVEL TOO HIGH
11.7. General checks
CAUTION!
THIS OPERATION IS RESERVED FOR THE AUTHORISED TECHNICAL SERVICES.
As a preventive maintenance measure, it is very important to ask the Authorised Technical Service for a
periodic overhaul of the machine.
Recommended interval: every year or every 3000 cycles.
If any element is found to be worn or damaged during the inspection, it should be renewed.
Maintenance
PROBABLE CAUSE
Excessive residual moisture in the
fabrics being dried
Insufficient drying time
Temperature too low
Inverter breakdown
Fault in the drum rotation detector
Faulty air intake filter
Poor air/gas mixture
Manual gas flow valve closed
Insufficient supply of gas
Gas ignition system defective or
ignition electrodes misplaced
Insufficient supply of gas
Excessive residual moisture in the
fabrics being dried
ACTION
Adjust the spin process.
Alter the program to increase the
drying time.
Alter the program to increase the
temperature.
Call
the
Authorised
Services.
Call
the
Authorised
Services.
Clean the filter.
Check, and if necessary correct,
the position of the venturi.
If the problem persists, contact the
Authorised Technical Services.
Open the manual gas flow valve.
Ask
a
Registered
Contractors to check the gas supply
pressure and flow rate.
If the problem persists, contact the
Authorised Technical Services.
Call
the
Authorised
Services.
Ask
a
Registered
Contractors to check the gas supply
pressure and flow rate.
If the problem persists, contact the
Authorised Technical Services.
Adjust the spin process.
57
Technical
Technical
Installation
Technical
Installation
Code no. 576074