11. USER MAINTENANCE INSTRUCTIONS

DANGER!
IT IS COMPULSORY TO CARRY OUT ALL THE INSPECTIONS AND TESTS REQUIRED BY THE
EXISTING LEGISLATION IN FORCE IN THE COUNTRY OR AREA IN WHICH THE MACHINE IS TO BE
USED, AT THE FREQUENCY DETERMINED BY THE AFOREMENTIONED LEGISLATION, ESPECIALLY
THOSE CONCERNING GAS APPLIANCES.
BEFORE MANIPULATING ANY OF THE MACHINE'S MECHANISMS, ENSURE THAT:
 THE AUTOMATIC EXTERNAL SWITCH IS DISCONNECTED AND MECHANICALLY LOCKED.
 THE MACHINE'S BREAKER SWITCH IS DISCONNECTED AND MECHANICALLY LOCKED (in
machines fitted with this device) (IF NECESSARY, REMOVE THE SWITCH'S REAR SUPPORT
COVER. THE SWITCH MUST BE IN THE "0" POSITION).
 THE MANUAL GAS SUPPLY VALVE IS CLOSED AND LOCKED (machines with gas heating).
 THERE ARE NO PARTS IN MOVEMENT DUE TO INERTIA.
 THE MACHINE IS COLD THROUGHOUT.
ONCE ANY MAINTENANCE OPERATION HAS ENDED:
 FIT ALL THE COVERS ON THE MACHINE.
 CONNECT THE ENERGY SOURCES.
 START A DRYING PROGRAM AND CHECK THAT THE MACHINE IS FUNCTIONING PROPERLY.
CAUTION!
FOLLOW THE INSTRUCTIONS PROVIDED. DOING SO WILL ENSURE AN EXCELLENT SERVICE,
REDUCE THE LIKELIHOOD OF FAULTS AND EXTEND THE LIFE OF THE DRYER.
USERS MUST REFRAIN FROM CARRYING OUT ANY MANIPULATION RESERVED FOR THE
AUTHORISED TECHNICAL SERVICE OR CLIENT TECHNICAL SERVICE.
THERE IS A MANUAL FOR MAINTENANCE OPERATIONS TO BE CARRIED OUT BY THE AUTHORISED
TECHNICAL SERVICE.
CAUTION!
SPECIFIC WARNINGS FOR GAS-HEATED DRYERS
GAS CIRCUIT:
Should the dryer be dismantled, on reassembling pay special attention to the order in which the
components are assembled. Ensure that the seals are fitted correctly and avoid over-tightening self-
tapping threads, since they can crack female components.
DANGER!
FLUFF AND SOOT ARE HIGHLY FLAMMABLE SUBSTANCES.
IT IS ESSENTIAL TO AVOID THESE BUILDING UP INSIDE THE MACHINE AND THE EXHAUST DUCTING
RUNNING FROM THE MACHINE TO THE OUTSIDE.
IT IS THEREFORE VERY IMPORTANT TO CLEAN THE AREAS EXPOSED TO LINT AND SOOT ON A
REGULAR BASIS (E.G.: COVERS, EXHAUST DUCTS, FILTER, FAN, ETC.). BY APPLYING THE
MAINTENANCE AND CLEANING PLAN SET OUT IN THIS CHAPTER ON A TIMELY BASIS. IN THE CASE
OF MACHINERY OPERATING IN ESPECIALLY DIRTY CONDITIONS, IT IS ESSENTIAL TO CLEAN MORE
FREQUENTLY.
KEEP THE AREA AROUND THE MACHINE FREE OF LINT AND FLAMMABLE SUBSTANCES.
Maintenance