Sony DVS-7250 Operation Software page 311

I/o expansion system
Hide thumbs Also See for DVS-7250:
Table of Contents

Advertisement

Path settings within an M/E bank or the PGM/PST bank
Making path settings for individual items within an M/E bank or
the PGM/PST bank
For example, in the case of the M/E-1 bank, use the following procedure.
For the M/E-2 and PGM/PST bank, use a corresponding procedure.
1
In the SWER KF PATH menu, press F2 (M/E-1).
The function key indications change as follows.
(F6 (CHR KEY) does not appear for the PGM/PST bank.)
KEY1
LINEAR
F1
2
Press one of F1 (KEY1) to F6 (CHR KEY) to select the corresponding
curve path type.
Pressing each of F1 to F6 cycles through the settings in the order shown
below. F1 (KEY1), F2 (KEY2), F4 (TRANS), and F6 (CHR KEY) cycle
through four settings excluding "SPLINE".
OFF t STEP t LINEAR t S-CURVE t SPLINE
The selected path type is shown on the menu display by an icon.
3
If you selected "SPLINE" in step 2, adjust control knobs 1 to 3 as
follows.
Knob
1
2
3
4
Press F10 (HUE PATH), then select the HUE path type.
For details, see steps 4 and 5 in the section "Setting the path for all
banks" (page 8-21).
CURVE
COLOR
KEY2
WIPE
TRANS
LINEAR
LINEAR
LINEAR
LINEAR
F2
F3
F4
Parameter
Setting
Tension
Degree of tension between points (–4.000 to +4.000)
Bias
Degree of inclination of tangent at point (–4.000 to +4.000)
Continuity
Degree of continuity at point (–4.000 to +4.000)
CHR
XPT
BKGD
KEY
DSBL
OFF
LINEAR
F5
F6
F7
F8
Chapter 8 Key Frame Effects
HUE
PATH
F9
F10
8-23