Signaling Request Interactions With Voice And Signaling Proxy; Table 16 Signaling Request Interaction With Signaling Proxy; Table 17 Signaling Request Interaction With Voice Proxy - Futurecom P25 Installation & Programming Manual

Digital vehicular repeater for apx series
Hide thumbs Also See for P25:
Table of Contents

Advertisement

Signaling Request Interactions with Voice and Signaling Proxy

When the DVR is in the process of handling a voice or signaling request for a PSU and
another Local PSU initiates a Signaling request, the DVRS will respond depending on its
programming and as described in Table 16 Signaling Request Interaction with Signaling
Proxy and Table 17 Signaling Request Interaction with Voice Proxy below. PSU
Emergency Alarm is considered high priority signaling. All other PSU signaling (such as
Status, Message etc.) is considered low priority.
New Request
High Priority Signaling
High Priority Signaling
Low Priority Signaling

Table 16 Signaling Request Interaction with Signaling Proxy

New Request
High Priority Signaling PSU Group Voice
High Priority Signaling PSU Individual Voice
High Priority Signaling Outbound FNE Group
High Priority Signaling Outbound FNE
Low Priority Signaling
Low Priority Signaling
Low Priority Signaling
Low Priority Signaling
Low Priority Signaling
H/L Priority Signaling
High Priority Signaling Individual Voice
Low Priority Signaling
Low Priority Signaling

Table 17 Signaling Request Interaction with Voice Proxy

January 2019
DVRS Installation & Programming Guide – PART II
Existing Request
High Priority Signaling
Low Priority Signaling
Low/High Priority Signaling
Existing Request
Voice
Individual Voice
PSU Group Voice
PSU Individual Voice
Outbound FNE Group
Voice
Outbound FNE Group
Voice
Outbound FNE
Individual Voice
Group Voice
Hangtime
Hangtime
Individual Voice
Hangtime
Individual Voice
Hangtime
APX Series P25 Interface
Action
Queue New Request
Process New Request
Queue New Request
'
Outbound
Takeover By
Signaling
Allowed'
Enabled or
Process New
Disabled
Request
Enabled or
Process New
Disabled
Request
Enabled or
Process New
Disabled
Request
Enabled or
Process New
Disabled
Request
Enabled or
Discard New
Disabled
Request
Enabled or
Discard New
Disabled
Request
Enabled
Process New
Request
Disabled
Discard New
Request
Enabled or
Discard New
Disabled
Request
Enabled or
Process New
Disabled
Request
Enabled or
Process New
Disabled
Request
Enabled
Process New
Request
Disabled
Discard New
Request
8M083X25 R14
Action
Page 103 of 153

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P25 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents