Permissible Ambient Conditions, Ventilation, Mounting Position; Conductor Cross-Sections - Kollmorgen ServoStar 400 Assembly & Installation

Digital servo amplifier
Hide thumbs Also See for ServoStar 400:
Table of Contents

Advertisement

Kollmorgen
2.9.5

Permissible ambient conditions, ventilation, mounting position

Storage temp. /humidity/duration
Transport temperature/humidity
Supply voltage tolerances
Ambient temperature in operation
Humidity in operation
Site altitude
Pollution level
Enclosure rating
Mounting position
Ventilation
2.9.6

Conductor cross-sections

Following EN 60204-1, we recommend :
AC connection
Motor cables
Resolver, motor thermostat
Encoder, motor thermostat
Analog signals
Control signals, BTB, DGND
Holding brake (motor)
+24 V / XGND
Technical requirements to cables ð p.33.
®
SERVOSTAR
400 Installation Manual
main power
SERVOSTAR 40xM
SERVOSTAR 44xM
auxiliary supply
w/o brake and w/o fan
with brake or with fan
Make sure that there is adequate forced ventilation
within the closed control cabinet.
07/05
ð p.67
ð p.67
min 1x115V
AC / max 1x230V
-10%
min 3x115V
AC / max 3x230V
-10%
min 3x230V
AC / max 3x400V
-10%
20 VDC ... 30 VDC
24 VDC (-0% +15%)
o
0...+45
C at rated conditions
+45...+55°C with power derating 2.5% / K
rel. humidity 85%, no condensation
up to 1000m amsl without restrictions
1000...2500m amsl with derating 1.5% / 100m
Pollution level 2 as per EN 60204 / EN 50178
IP 20
normally vertical ð p.25
SERVOSTAR4x3: free convection
SERVOSTAR4x6: add-on fan (ð p.66)
1.5 mm², depending on the system fusing
1 mm², shielded, capacitance <150pF/m,
max. 25m
4x2x0.25 mm², twisted pairs, shielded, max.100m,
capacitance <120pF/m
7x2x0.25 mm², twisted pairs, shielded, max. 50m,
capacitance <120pF/m
0.25 mm² , twisted pairs, shielded
0.5 mm²
0.75 mm², shielded, check voltage drop
max. 2.5 mm², check voltage drop
Technical description
+10%
, 50/60 Hz
+10%
, 50/60 Hz
+10%
, 50/60 Hz
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents