3.4.5.2

Requirements to cables

Further information on the chemical, mechanical and electrical characteristics of the
cables can be obtained from our customer support.
Insulation material
Sheathing
Core insulation
Capacitance
Motor cable
RES/encoder cable
Technical data
(4x1.0+(2x0.75))
®
SERVOSTAR
400 Installation Manual
PUR (polyurethane, code 11Y)
PETP (polyesteraphthalate, code 12Y)
less than 150 pF/m
less than 120 pF/m
The brackets in the cable designation indicate the shielding.
All cables are suitable for use as trailing cables.
The technical data refer to the use as moveable cables.
operating life : 1 million bending cycles
The permissible operating temperature range is from -30°C to +80°C.
All cables are colour-coded according to IEC 757.
Cores
External diameter
[mm²]
(4x1.0)
(4x2x0.25)
(7x2x0.25)
(10x2x0.14)
07/05
Bending radius
[mm]
[mm]
10
100
10.5
100
6.9
60
9.9
80
8.8
80