Rs232 Interface, Pc Connection (X8), Master Only - Kollmorgen ServoStar 400 Assembly & Installation

Digital servo amplifier
Hide thumbs Also See for ServoStar 400:
Table of Contents

Advertisement

Kollmorgen
4.10

RS232 interface, PC connection (X8), master only

The setting of the operating, position control, and motion-block parameters, can be car-
ried out by using the setup software on an ordinary commercial PC.
Connect the PC interface (X8) of the servo amplifier while the supply to the equipment
is switched off via a null-modem cable to a serial interface on the PC (do not use a
null-modem link cable!).
The interface has the same potential as the internal logic, and uses AGND as the ground
reference.
The interface is selected and set up in the setup software.
Further notes can be found on page 34 .
Interface cable between the PC and servo amplifiers of the SERVOSTAR 400 series:
(View: front view of the built-in SubD connectors, this corresponds to looking at the solder
side of the SubD connector on the cable.)
®
SERVOSTAR
400 Installation Manual
SERVOSTAR 400
07/05
Interfaces
51