Installation Guide Linear Rotary Motors
3.3 Mounting the load on the shaft
The load mass is mounted either by means of a feather key or a shaft-hub clamping.
For the first mounting variant, a feather key slot is incorporated at the end of the shaft.
The shaft-hub clamping is a non-positive connection which is produced by means of two conical rings. The
use of drivers or the production of grooves is completely eliminated. The suitable shaft-hub clamping type
can be ordered from LinMot. Mounting instructions and ordering information can be found in the
"Accessories" chapter.
3.4 Connection of air
The PR02-52 is optionally equipped with an air connection. At the rear of the motor, above the electrical
connectors, there is a pneumatic push-in fitting (external hexagon M5) for a Ø 4 mm hose. Inside the motor,
a Ø 4 mm air hose is laid along the rotating shaft, which has a continuous hole diameter of Ø 2.5 mm.
This enables the user to implement pneumatic applications with an operating pressure of max. 6 bar.
In the case of vacuum application, it is recommended to use a unit with sufficient power, as experience has
shown that all air coupling points generate small losses.
Page 8 / 24
6
5
PR02-52
ENG
Feather key slot
Push-in fitting
External hexagon M5
NTI AG / LinMot