Mounting The Motor - LinMot P01-48-HP Series Installation Manual

Linear motors
Table of Contents

Advertisement

Installation Guide Linear Motors

4.2 Mounting the motor

Please attend to the safety instructions in the chapter 2 during the assembling!
Groove
Page 28 / 47
1. Installing the external bearing (front).
Pos .1: Hexagon head screw M6 x 35
(Torque = 6 Nm)
Pos. 2: Wiper
Pos. 3: Bearing (PB01) or Bearing flange
(PB03)
2. Installing the external bearing (rear).
3. Insert the slider into the stator.
After installation, the notch of the slider is
located on the connector side.
4. If fluid cooling is used, remove headless
screws.
For the stator variant with liquid cooling, the
headless screws must be removed and
replaced with the corresponding threaded
plugs. See additional details in Paragraph 4.8.5
P01-48-HP EX protected
Mount the bearing / bearing flange
with care, since the plastic sleeve may
break.
The corresponding bearings must be
ordered separately! A selection can be
found in section 3.4.
The slider is magnetically attracted.
ENG