2. Verify that the mounted position meets the bearing requirements. Otherwise,
you are advised to reinforce the mounted position to support the device weight.
For more information, see the product datasheet.
3. Verify lightning protection and grounding requirements
4. Ground the terminal properly.
NOTE:
When mounting the camera, please install the bracket
adapter to the bracket first and then mount the camera to the bracket.
Tighten all the screws to hold the camera securely.
Power Connection
The camera provides two methods of power inputs, either
Power up the camera
NOTE:
Do not turn on the power nor connect the power/POE to the camera Tail Cable until the camera Tail Cable has been
connected completely to the camera.
Use 12VDC or IEEE802.3at standard POE power adaptor or POE switch to power the camera. It takes about 2 minutes for
the camera to be completely powered on.
NOTE:
Use water proof / IP67 rated junction box/ connection box to protect the RJ45 and other connections.
Control Connection
RS422 (VISCA) connection
1.
Only B class supports VISCA control., S class does not support VISCA control
2.
Follow the connection below to make the RS422 control connection for the keyboard controller.
3.
The camera default address is set to 1, default Baud Rate is set to 9600.
4.
Set the keyboard controller Baud Rate to 9600. The Baud Rate of the camera and the controller must be the same. The controller
must be VISCA compatible.
Use the keyboard controller to change the camera address using the camera's OSD menu.
5.
POE (IEEE802.3at)
or 12VDC.