For control details, refer to Operating Instructions of control keyboard/station software.
You need to match the communication speed (Baud Rate) between the camera and the joystick controller.
Operating Multiple Cameras Using RS422/485
Using RS-422 (VISCA), you can connect to 7 cameras.
Using RS-485 (PELCO), you can connect to 255 cameras.
Using RS-485 (PELCO), all camera addresses must be set up before the connection. You can set the camera address
by operating OSD menu. In this case, you can use multiple control keyboards.
VISCA over IP Control
With VISCA over IP function, you can control the camera using VISCA protocol on a controller equipped with IP
communication capabilities via LAN.
The communication specifications of VISCA over IP are follows:
1. Interface
RJ-45 10/100M
2. Interface protocol
IPv4
3. Transport protocol
UDP
4. IP address (Default:192.168.0.13)
5. Port: 52381
VISCA over IP Network Configuration
Re-assign the camera
The default information of the IP camera is following:
Static IP: 192.168.0.13
Subnet mask: 255.255.255.0
Gateway: 192.168.0.1
VISCA over IP control port: 52381.
The camera IP address needs to be assigned to the IP address
that works with your local network.
Controlling via VISCA over IP