Display / response of active program controls:
If a program control is activated, the abbreviation of the corresponding function appears in
the status display as response.
Proceed as follows
See also
Defining the dry run feedrate (Page 122)
3.7.2
Skip blocks
It is possible to skip program blocks, which are not to be executed every time the program
runs.
The skip blocks are identified by placing a "/" (forward slash) or "/x (x = number of skip level)
character in front of the block number. Several consecutive blocks can also be skipped.
The statements in the skipped blocks are not executed, i.e. the program continues with the
next block, which is not skipped.
The number of skip levels that can be used depends on a machine datum.
HMI sl Universal
Operating Manual, 01/2008, 6FC5398-6AP10-2BA0
1.
Select the "Machine" operating area.
2.
Press the "AUTO" or "MDA" key.
...
3.
Press the "Prog. cntrl." softkey.
The "Program control" window appears.
Machine the workpiece
3.7 Controlling the program run
91