www.DataSheet4U.com
15.1 Functions of Power-on-Clear Circuit
The power-on-clear circuit (POC) has the following functions.
• Generates internal reset signal at power on.
• Compares supply voltage (V
when V
DD
Cautions 1. If an internal reset signal is generated in the POC circuit, the reset control flag register
www.DataSheet4U.com
2. Because the detection voltage (V
Remark This product incorporates multiple hardware functions that generate an internal reset signal. A flag that
indicates the reset cause is located in the reset control flag register (RESF) for when an internal reset
signal is generated by the watchdog timer (WDT) or low-voltage-detection (LVI) circuit. RESF is not
cleared to 00H and the flag is set to 1 when an internal reset signal is generated by WDT or LVI.
For details of RESF, see CHAPTER 14 RESET FUNCTION.
244
CHAPTER 15 POWER-ON-CLEAR CIRCUIT
) and detection voltage (V
DD
< V
.
POC
(RESF) is cleared to 00H.
voltage in the range of 2.2 to 5.5 V.
Preliminary User's Manual U16898EJ1V0UD
= 2.1 V ±0.1 V), and generates internal reset signal
POC
) of the POC circuit is in a range of 2.1 V ±0.1 V, use a
POC