www.DataSheet4U.com
Figure 6-22. Timing of Pulse Width Measurement Operation with Free-Running Counter
Count clock
TM00 count value
TI000 pin input
CR010 capture value
INTTM010
www.DataSheet4U.com
TI010 pin input
CR000 capture value
INTTM000
OVF00
Note OVF00 must be cleared by software.
100
CHAPTER 6 16-BIT TIMER/EVENT COUNTER 00
(with Both Edges Specified)
t
0000H
0001H
D0
D0 + 1
D0
(D1 − D0) × t
Preliminary User's Manual U16898EJ1V0UD
D1
D1 + 1
FFFFH
0000H
D1
D1
(10000H − D1 + D2) × t
(10000H − D1 + (D2 + 1)) × t
D2
D2 + 1 D2 + 2
D3
D2
D2 + 1
Note
(D3 − D2) × t