Registers Used During Standby - NEC 78K0S/KA1+ Preliminary User's Manual

8-bit single-chip microcontrollers
Hide thumbs Also See for 78K0S/KA1+:
Table of Contents

Advertisement

www.DataSheet4U.com

13.1.2 Registers used during standby

The oscillation stabilization time after the standby mode is released is controlled by the oscillation stabilization time
select register (OSTS).
Remark For the registers that start, stop, or select the clock, see CHAPTER 5 CLOCK GENERATORS.
(1) Oscillation stabilization time select register (OSTS)
This register is used to select oscillation stabilization time of the clock supplied from the oscillator when the
STOP mode is released. The wait time set by OSTS is valid only when the crystal/ceramic oscillation clock is
selected as the system clock and after the STOP mode is released. If the high-speed Ring-OSC oscillator or
external clock input is selected as the system clock source, no wait time elapses.
The system clock oscillator and the oscillation stabilization time that elapses after power application or release
www.DataSheet4U.com
of reset are selected by the option byte. For details, refer to CHAPTER 17 OPTION BYTE.
OSTS is set by using the 8-bit memory manipulation instruction.
Address: FFF4H, After reset: Undefined, R/W
Symbol
OSTS
OSTS1
Cautions 1. To set and then release the STOP mode, set the oscillation stabilization time as follows.
Remarks 1. ( ): f
228
CHAPTER 13 STANDBY FUNCTION
Figure 13-1. Format of Oscillation Stabilization Time Select Register (OSTS)
7
6
5
0
0
0
OSTS0
10
0
0
2
/f
(102.4
X
12
0
1
2
/f
(409.6
X
15
1
0
2
/f
(3.27 ms)
X
17
1
1
2
/f
(13.1 ms)
X
Expected oscillation stabilization time of resonator ≤ Oscillation stabilization time set
by OSTS
2. The wait time after the STOP mode is released does not include the time from the
release of the STOP mode to the start of clock oscillation ("a" in the figure below),
regardless of whether STOP mode was released by reset input or interrupt generation.
Voltage
waveform
of X1 pin
3. The oscillation stabilization time that elapses on power application or after release of
reset is selected by the option byte. For details, refer to CHAPTER 17 OPTION BYTE.
= 10 MHz
X
2. Determine the oscillation stabilization time of the resonator by checking the characteristics of
the resonator to be used.
Preliminary User's Manual U16898EJ1V0UD
4
3
0
0
Selection of oscillation stabilization time
µ
s)
µ
s)
STOP mode is released
a
2
1
0
0
OSTS1
OSTS0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpd78f9221Mpd78f9222