Specifications
Mains Supply 3 x 525- 690V AC
FC 302
High/ Normal Load*
Typical Shaft output at 550V
[kW]
Typical Shaft output at 575V
[HP]
Typical Shaft output at 690V
[kW]
Enclosure IP21, 55
Output current
Continuous
(3 x 525-550V) [A]
Intermittent (60 sec
overload)
(3 x 525-550V) [A]
Continuous
(3 x 551-690V) [A]
Intermittent (60 sec
overload)
(3 x 551-690V) [A]
Continuous KVA
(at 550V) [KVA]
Continuous KVA
(at 575V) [KVA]
Continuous KVA
(at 690V) [KVA]
Max. input current
Continuous
(at 550V) [A]
Continuous
(at 575V) [A]
Additional specifications
Max. cable size, mains,
motor, load share and brake
2
[mm
(AWG)]
Estimated power loss
at rated max. load [W]
Weight,
enclosure IP21, IP55 [kg]
Efficiency
0
10
For fuse ratings, see 10.3.1 Fuses
1) High overload = 160% torque during 60 sec., Normal overload = 110% torque during 60 sec.
2) American Wire Gauge.
3) Measured using 5 m screened motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within +/-15% (tolerence relates to variety
in voltage and cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the
power loss in the frequency converter and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
LCP and typical control card power consumptions are included. Further options and customer load may add up to 30W
to the losses. (Though typical only 4W extra for a fully loaded control card, or options for slot A or slot B, each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed
for (+/-5%).
70
VLT
Instructions
P30K
HO
NO
22
30
30
40
30
37
C2
36
43
54
47.3
34
41
51
45.1
34.3
41.0
33.9
40.8
40.6
49.0
36
49
54
53.9
480
4)
4)
0.98
MG.33.AJ.02 - VLT
®
AutomationDrive Operating
P37K
HO
NO
HO
30
37
37
40
50
50
37
45
45
C2
43
54
54
64.5
59.4
81
41
52
52
61.5
57.2
78
41.0
51.4
51.4
40.8
51.8
51.8
49.0
62.1
62.1
49
59
59
72
64.9
87
95 (4/0)
592
0.98
®
is a registered Danfoss trademark
P45K
P55K
NO
HO
NO
45
45
55
60
60
75
55
55
75
C2
C2
65
65
87
71.5
97.5
95.7
62
62
83
68.2
93
91.3
61.9
61.9
82.9
61.7
61.7
82.7
74.1
74.1
99.2
71
71
87
78.1
105
95.7
720
880
65
0.98
0.98
P75K
HO
NO
55
75
75
100
75
90
C2
87
105
130.5
115.5
83
100
124.5
110
82.9
100.0
82.7
99.6
99.2
119.5
87
99
129
108.9
1200
0.98